電梯遠(yuǎn)程監(jiān)測系統(tǒng)的設(shè)計(jì)
發(fā)布時(shí)間:2008/8/27 0:00:00 訪問次數(shù):313
摘要:本文首先介紹了應(yīng)用電梯遠(yuǎn)程檢測系統(tǒng)這項(xiàng)技術(shù)的意義,然后給出了電梯遠(yuǎn)程監(jiān)測系統(tǒng)的組成結(jié)構(gòu),并注重介紹數(shù)據(jù)采集終端的硬件構(gòu)成,及其完成的主要功能,最后較詳細(xì)地介紹了采集終端以及上位pc機(jī)的軟件設(shè)計(jì)。
design of remote elevator monitory system
chen fei 1 yang huajiang 1jiang bo 2
。1、xinjiang uygur autonomous region special equipment examination research institute,830000;2、xinjiang university,83008)
abstract: the article first introduced applies elevator remote probe system this technology the significance, then has given the elevator remote monitory system‘s composition structure, and pays great attention to introduce the data acquisition terminal the hardware constitution, and completes the major function, the communication procedure and the software flow chart between the data acquiring terminal and the remote pc are presented.
key words: elevator; remote monitory; data acquiring
1前言
隨著國民經(jīng)濟(jì)的快速發(fā)展,大中城市里的高層建筑越來越多,電梯這一必不可少的設(shè)備的數(shù)量也隨之激增,由于它直接關(guān)系到用戶的生命安危,因此國家規(guī)定,每年要由專門的質(zhì)量監(jiān)督部門對其進(jìn)行強(qiáng)制檢測。傳統(tǒng)的年檢方法是派出專門的工作人員趕赴現(xiàn)場,查看電梯值班記錄,人工檢驗(yàn)各項(xiàng)指標(biāo),既費(fèi)時(shí)費(fèi)力,又不能客觀如實(shí)地反映電梯長期的狀態(tài)和性能。筆者開發(fā)的遠(yuǎn)程監(jiān)測系統(tǒng),在每部電梯的運(yùn)行現(xiàn)場安裝一臺(tái)采集終端, 24小時(shí)不間斷監(jiān)測并記錄電梯的運(yùn)行狀況,需要年檢時(shí),通過電話線遠(yuǎn)程將分布在城市不同地點(diǎn)的電梯的歷史數(shù)據(jù)和實(shí)時(shí)數(shù)據(jù)取回到質(zhì)量監(jiān)督部門的上位管理計(jì)算機(jī)上,由專用評估軟件對電梯運(yùn)行情況進(jìn)行分析,從而客觀準(zhǔn)確地對電梯的性能進(jìn)行評判。
2 系統(tǒng)組成結(jié)構(gòu)圖
系統(tǒng)組成結(jié)構(gòu)圖如圖1所示,該系統(tǒng)由遠(yuǎn)程上位管理計(jì)算機(jī)以及多臺(tái)采集終端組成。每臺(tái)采集終端連接一部電梯,實(shí)時(shí)采集該電梯運(yùn)行的各種狀態(tài),并對數(shù)據(jù)進(jìn)行分析和處理,將電梯的故障信息保存到非易失性存儲(chǔ)器中;遠(yuǎn)程上位管理計(jì)算機(jī)用于管理和評估電梯性能,需要年檢時(shí),通過計(jì)算機(jī)上的調(diào)制解調(diào)器接入公共電話網(wǎng)絡(luò)(pstn)呼叫現(xiàn)場的采集終端,將現(xiàn)場的數(shù)據(jù)錄入到上位機(jī)的數(shù)據(jù)庫中進(jìn)行分析和評判,從而得到電梯是否合格的結(jié)論。為了節(jié)約電話線路資源,某個(gè)地域范圍較小的建筑群(例如相鄰距離在1千米內(nèi)的幾幢大樓)共用一根電話線路,只將1號采集終端接入電話網(wǎng)絡(luò),該建筑群其余的采集終端與1號終端一起掛在485總線上,通過軟件協(xié)議識別終端號并與上位機(jī)通信。
圖1 系統(tǒng)組成結(jié)構(gòu)圖
3 采集終端的硬件設(shè)計(jì)
電梯需要監(jiān)測的各類信息,例如平層信號、轎門閉鎖、廳門閉鎖、上下極限以及運(yùn)行加速度、溫濕度等信號,經(jīng)過信號調(diào)用處理或經(jīng)傳感器電路變換,最終提供給采集終端的是標(biāo)準(zhǔn)開關(guān)量或模擬量?紤]到實(shí)際情況及成本可采用開關(guān)量輸入為16路,模擬量為8路的8位mcu(微控制器),采集終端應(yīng)考慮的主要技術(shù)數(shù)據(jù)如:采集周期、通信協(xié)議、通信速率、開關(guān)量采集、模擬量采集、數(shù)據(jù)存儲(chǔ)量等等。采集終端的硬件框圖如圖2所示,在圖2中,使用調(diào)制解調(diào)器模塊,并通過電話網(wǎng)絡(luò)實(shí)現(xiàn)與遠(yuǎn)程上位機(jī)的modem通信,其輸出經(jīng)電平轉(zhuǎn)換芯片變?yōu)闃?biāo)準(zhǔn)的rs485電平后與安裝在附近電梯上的其他采集終端組成rs485網(wǎng)絡(luò);鎖存器用于對輸入的開關(guān)量進(jìn)行鎖存和采集; a /d轉(zhuǎn)換器,完成對模擬量的采集;時(shí)鐘芯片為整個(gè)系統(tǒng)提供精確的時(shí)間基準(zhǔn),它可以產(chǎn)生年、月、日、時(shí)、分、秒、星期等實(shí)時(shí)數(shù)據(jù),并且內(nèi)置鋰電池和時(shí)鐘電路,無需外部供電即可獨(dú)立運(yùn)行;mcu擴(kuò)展模塊用于補(bǔ)充mcu的功能,可以增加類似于具有掉電保護(hù)功能,也可以用來擴(kuò)大存儲(chǔ)空間使其某部電梯能儲(chǔ)存長達(dá)1年的歷史故障數(shù)據(jù)。
圖2 采集終端的硬件框圖
4 軟件的設(shè)計(jì)
4.1 采集終端的數(shù)據(jù)采集軟件設(shè)計(jì)
采集終端的軟件采用visual basic 語言編寫,其中的數(shù)據(jù)采集部分包括對開關(guān)量和模擬量的查詢以及對故障的判斷,還包括對故障按照一定格式進(jìn)行存儲(chǔ)。該部分的軟件工作于定時(shí)查詢的方式,定時(shí)時(shí)間為1s,即每秒鐘對16路開關(guān)量和8路模擬量進(jìn)行查詢,若某路有故障并符合存儲(chǔ)條件,則將該路故障的編號以及時(shí)間標(biāo)記一起存儲(chǔ)到e2prom中。數(shù)據(jù)采集部分的軟件流程如圖3所示。
圖3 數(shù)據(jù)采集軟件流程圖
4.2采集終端的通信軟件設(shè)計(jì)
采集終端的modem模塊工作于被叫方式
摘要:本文首先介紹了應(yīng)用電梯遠(yuǎn)程檢測系統(tǒng)這項(xiàng)技術(shù)的意義,然后給出了電梯遠(yuǎn)程監(jiān)測系統(tǒng)的組成結(jié)構(gòu),并注重介紹數(shù)據(jù)采集終端的硬件構(gòu)成,及其完成的主要功能,最后較詳細(xì)地介紹了采集終端以及上位pc機(jī)的軟件設(shè)計(jì)。
design of remote elevator monitory system
chen fei 1 yang huajiang 1jiang bo 2
。1、xinjiang uygur autonomous region special equipment examination research institute,830000;2、xinjiang university,83008)
abstract: the article first introduced applies elevator remote probe system this technology the significance, then has given the elevator remote monitory system‘s composition structure, and pays great attention to introduce the data acquisition terminal the hardware constitution, and completes the major function, the communication procedure and the software flow chart between the data acquiring terminal and the remote pc are presented.
key words: elevator; remote monitory; data acquiring
1前言
隨著國民經(jīng)濟(jì)的快速發(fā)展,大中城市里的高層建筑越來越多,電梯這一必不可少的設(shè)備的數(shù)量也隨之激增,由于它直接關(guān)系到用戶的生命安危,因此國家規(guī)定,每年要由專門的質(zhì)量監(jiān)督部門對其進(jìn)行強(qiáng)制檢測。傳統(tǒng)的年檢方法是派出專門的工作人員趕赴現(xiàn)場,查看電梯值班記錄,人工檢驗(yàn)各項(xiàng)指標(biāo),既費(fèi)時(shí)費(fèi)力,又不能客觀如實(shí)地反映電梯長期的狀態(tài)和性能。筆者開發(fā)的遠(yuǎn)程監(jiān)測系統(tǒng),在每部電梯的運(yùn)行現(xiàn)場安裝一臺(tái)采集終端, 24小時(shí)不間斷監(jiān)測并記錄電梯的運(yùn)行狀況,需要年檢時(shí),通過電話線遠(yuǎn)程將分布在城市不同地點(diǎn)的電梯的歷史數(shù)據(jù)和實(shí)時(shí)數(shù)據(jù)取回到質(zhì)量監(jiān)督部門的上位管理計(jì)算機(jī)上,由專用評估軟件對電梯運(yùn)行情況進(jìn)行分析,從而客觀準(zhǔn)確地對電梯的性能進(jìn)行評判。
2 系統(tǒng)組成結(jié)構(gòu)圖
系統(tǒng)組成結(jié)構(gòu)圖如圖1所示,該系統(tǒng)由遠(yuǎn)程上位管理計(jì)算機(jī)以及多臺(tái)采集終端組成。每臺(tái)采集終端連接一部電梯,實(shí)時(shí)采集該電梯運(yùn)行的各種狀態(tài),并對數(shù)據(jù)進(jìn)行分析和處理,將電梯的故障信息保存到非易失性存儲(chǔ)器中;遠(yuǎn)程上位管理計(jì)算機(jī)用于管理和評估電梯性能,需要年檢時(shí),通過計(jì)算機(jī)上的調(diào)制解調(diào)器接入公共電話網(wǎng)絡(luò)(pstn)呼叫現(xiàn)場的采集終端,將現(xiàn)場的數(shù)據(jù)錄入到上位機(jī)的數(shù)據(jù)庫中進(jìn)行分析和評判,從而得到電梯是否合格的結(jié)論。為了節(jié)約電話線路資源,某個(gè)地域范圍較小的建筑群(例如相鄰距離在1千米內(nèi)的幾幢大樓)共用一根電話線路,只將1號采集終端接入電話網(wǎng)絡(luò),該建筑群其余的采集終端與1號終端一起掛在485總線上,通過軟件協(xié)議識別終端號并與上位機(jī)通信。
圖1 系統(tǒng)組成結(jié)構(gòu)圖
3 采集終端的硬件設(shè)計(jì)
電梯需要監(jiān)測的各類信息,例如平層信號、轎門閉鎖、廳門閉鎖、上下極限以及運(yùn)行加速度、溫濕度等信號,經(jīng)過信號調(diào)用處理或經(jīng)傳感器電路變換,最終提供給采集終端的是標(biāo)準(zhǔn)開關(guān)量或模擬量?紤]到實(shí)際情況及成本可采用開關(guān)量輸入為16路,模擬量為8路的8位mcu(微控制器),采集終端應(yīng)考慮的主要技術(shù)數(shù)據(jù)如:采集周期、通信協(xié)議、通信速率、開關(guān)量采集、模擬量采集、數(shù)據(jù)存儲(chǔ)量等等。采集終端的硬件框圖如圖2所示,在圖2中,使用調(diào)制解調(diào)器模塊,并通過電話網(wǎng)絡(luò)實(shí)現(xiàn)與遠(yuǎn)程上位機(jī)的modem通信,其輸出經(jīng)電平轉(zhuǎn)換芯片變?yōu)闃?biāo)準(zhǔn)的rs485電平后與安裝在附近電梯上的其他采集終端組成rs485網(wǎng)絡(luò);鎖存器用于對輸入的開關(guān)量進(jìn)行鎖存和采集; a /d轉(zhuǎn)換器,完成對模擬量的采集;時(shí)鐘芯片為整個(gè)系統(tǒng)提供精確的時(shí)間基準(zhǔn),它可以產(chǎn)生年、月、日、時(shí)、分、秒、星期等實(shí)時(shí)數(shù)據(jù),并且內(nèi)置鋰電池和時(shí)鐘電路,無需外部供電即可獨(dú)立運(yùn)行;mcu擴(kuò)展模塊用于補(bǔ)充mcu的功能,可以增加類似于具有掉電保護(hù)功能,也可以用來擴(kuò)大存儲(chǔ)空間使其某部電梯能儲(chǔ)存長達(dá)1年的歷史故障數(shù)據(jù)。
圖2 采集終端的硬件框圖
4 軟件的設(shè)計(jì)
4.1 采集終端的數(shù)據(jù)采集軟件設(shè)計(jì)
采集終端的軟件采用visual basic 語言編寫,其中的數(shù)據(jù)采集部分包括對開關(guān)量和模擬量的查詢以及對故障的判斷,還包括對故障按照一定格式進(jìn)行存儲(chǔ)。該部分的軟件工作于定時(shí)查詢的方式,定時(shí)時(shí)間為1s,即每秒鐘對16路開關(guān)量和8路模擬量進(jìn)行查詢,若某路有故障并符合存儲(chǔ)條件,則將該路故障的編號以及時(shí)間標(biāo)記一起存儲(chǔ)到e2prom中。數(shù)據(jù)采集部分的軟件流程如圖3所示。
圖3 數(shù)據(jù)采集軟件流程圖
4.2采集終端的通信軟件設(shè)計(jì)
采集終端的modem模塊工作于被叫方式
熱門點(diǎn)擊
- 手機(jī)定位技術(shù)
- 通信有效性與可靠性
- SPI通信原理及通信協(xié)議
- EPON設(shè)備互通性
- RF器件的鄰道泄漏比(ACLR)來源
- Access數(shù)據(jù)庫出現(xiàn)0x80004005問
- 手機(jī)定位的定義
- GPS 格式解析
- Rockwell AB PLC和PROFIB
- 在控制中心點(diǎn)選數(shù)據(jù)庫時(shí)出現(xiàn)的SQL1031N
推薦技術(shù)資料
- MPS 啟動(dòng)器開發(fā)板/評估套件(EVKT/P
- 12V、6A 四路降壓電源管理 IC
- 數(shù)字恒定導(dǎo)通時(shí)間控制模式(COT)
- 同步降壓PWM DC-DC線性
- ADC 技術(shù)參數(shù)與應(yīng)用需求之
- 反激變換器傳導(dǎo)和輻射電磁干擾分
- 多媒體協(xié)處理器SM501在嵌入式系統(tǒng)中的應(yīng)用
- 基于IEEE802.11b的EPA溫度變送器
- QUICCEngine新引擎推動(dòng)IP網(wǎng)絡(luò)革新
- SoC面世八年后的產(chǎn)業(yè)機(jī)遇
- MPC8xx系列處理器的嵌入式系統(tǒng)電源設(shè)計(jì)
- dsPIC及其在交流變頻調(diào)速中的應(yīng)用研究